Adjust metering rod after pump adjusting is made. Insert metering rod gauge in place of metering rod, seating tapered end in jet. With throttle valve seated, there should be less than .005” clearance between metering rod pin and should of notch in gauge. Adjustment can be made by bending metering rod pin portion of pump arm up or down.